How to enable "Restore on AC Power Loss" function in Crystal and CT-8000IP?

[Question]

After power lost, Crystal will shut down suddenly and cannot be turned on automatically even thought the power coming back. The only way is rebooting Crystal manually. How to enable "Restore on AC Power Loss" function in Crystal server?

[Solution]

User can adjust the BIOS setting to enable this function. Please follow below instruction to enter in BIOS:

(1) Connect monitor to Crystal.

(2) Boot Crystal. Press "DEL" continuously when you see below screen.

(3) Adjust AC power setting refer to below snapshot:

Old 4 bay model (CT-4000/4000R):

Path: Chipset  >>> South Bridge Configuration >>> Restore AC Power Loss then select "Power ON". 

New Crystal 4 bays and tower (R1- 0400CT and TR-0400CT):
Path: Chipset  >>> Restore AC Power Loss then select "Power ON".

Crystal 8 bays (CT-8000R/RP/IP):
Path: Chipset  >>> PCH-IO Configuration >>> South Bridge Configuration >>> Restore AC Power Loss then select "Power ON". 

(4) After adjusting finished, select "Exit" then press "F10" to save the configuration and exit the BIOS.